Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Imaging ; 104: 110008, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37862910

RESUMO

PURPOSE: Photon-counting-detector computed tomography (PCD-CT) offers enhanced noise reduction, spatial resolution, and image quality in comparison to energy-integrated-detectors CT (EID-CT). These hypothesized improvements were compared using PCD-CT ultra-high (UHR) and standard-resolution (SR) scan-modes. METHODS: Phantom scans were obtained with both EID-CT and PCD-CT (UHR, SR) on an adult body-phantom. Radiation dose was measured and noise levels were compared at a minimum achievable slice thickness of 0.5 mm for EID-CT, 0.2 mm for PCD-CT-UHR and 0.4 mm for PCD-CT-SR. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated for five tissue densities. Additionally, data from 25 patients who had PCD-CT of chest were reconstructed at 1 mm and 0.2 mm (UHR) slice-thickness and compared quantitatively (SNR) and qualitatively (noise, quality, sharpness, bone details). RESULTS: Phantom PCD-CT-UHR and PCD-CT-SR scans had similar measured radiation dose (16.0mGy vs 15.8 mGy). Phantom PCD-CT-SR (0.4 mm) had lower noise level in comparison to EID-CT (0.5 mm) (9.0HU vs 9.6HU). PCD-CT-UHR (0.2 mm) had slightly higher noise level (11.1HU). Phantom PCD-CT-SR (0.4 mm) had higher SNR in comparison to EID-CT (0.5 mm) while achieving higher resolution (Bone 115 vs 96, Acrylic 14 vs 14, Polyethylene 11 vs 10). SNR was slightly lower across all densities for PCD-CT UHR (0.2 mm). Interestingly, CNR was highest in the 0.2 mm PCD-CT group; PCD-CT CNR was 2.45 and 2.88 times the CNR for 0.5 mm EID-CT for acrylic and poly densities. Clinical comparison of SNR showed predictably higher SNR for 1 mm (30.3 ± 10.7 vs 14.2 ± 7, p = 0.02). Median subjective ratings were higher for 0.2 mm UHR vs 1 mm PCD-CT for nodule contour (4.6 ± 0.3 vs 3.6 ± 0.1, p = 0.02), bone detail (5 ± 0 vs 4 ± 0.1, p = 0.001), image quality (5 ± 0.1 vs 4.6 ± 0.4, p = 0.001), and sharpness (5 ± 0.1 vs 4 ± 0.2). CONCLUSION: Both UHR and SR PCD-CT result in similar radiation dose levels. PCD-CT can achieve higher resolution with lower noise level in comparison to EID-CT.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Adulto , Humanos , Tomografia Computadorizada por Raios X/métodos , Pulmão , Doses de Radiação , Razão Sinal-Ruído , Imagens de Fantasmas
2.
Biomed Mater Eng ; 30(3): 323-331, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31006658

RESUMO

Calcium phosphate cement (CPC) has been studied extensively due to its bioactivity and biodegradability. CPC is typically made by a combination of multiple calcium phosphates that form a paste that sets and hardens in the body after being combined with either water or an aqueous solution. It is highly moldable and easily manipulated, and CPCs possess osteoconductive properties. Due to these characteristics, CPCs offer great promise in bone grafting applications. CPC combined with drugs has a great potential as drug delivery system and has been studied extensively. In this review we have focused on Bisphosphonate-CPC drug delivery system. In addition, we introduce and discuss the potential of studying other bisphosphonates.


Assuntos
Conservadores da Densidade Óssea/administração & dosagem , Fosfatos de Cálcio/química , Difosfonatos/química , Portadores de Fármacos/química , Alendronato/administração & dosagem , Animais , Materiais Biocompatíveis/química , Sistemas de Liberação de Medicamentos/métodos , Ácido Etidrônico/administração & dosagem , Humanos , Pamidronato/administração & dosagem , Ácido Zoledrônico/administração & dosagem
3.
Theranostics ; 6(11): 1975-1987, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27698934

RESUMO

Degeneration of elastic lamina and vascular calcification are common features of vascular pathology such as aortic aneurysms. We tested whether dual therapy with targeted nanoparticles (NPs) can remove mineral deposits (by delivery of a chelating agent, ethylene diamine tetraacetic acid (EDTA)) and restore elastic lamina (by delivery of a polyphenol, pentagalloyl glucose (PGG)) to reverse moderate aneurysm development. EDTA followed by PGG NP delivery led to reduction in macrophage recruitment, matrix metalloproteinase (MMP) activity, elastin degradation and calcification in the aorta as compared to delivery of control blank NPs. Such dual therapy restored vascular elastic lamina and improved vascular function as observed by improvement in circumferential strain. Therefore, dual targeted therapy may be an attractive option to remove mineral deposits and restore healthy arterial structures in moderately developed aneurysms.


Assuntos
Aneurisma Aórtico/tratamento farmacológico , Quelantes de Cálcio/administração & dosagem , Ácido Edético/administração & dosagem , Taninos Hidrolisáveis/administração & dosagem , Nanopartículas/administração & dosagem , Polifenóis/administração & dosagem , Calcificação Vascular/tratamento farmacológico , Animais , Aneurisma Aórtico/patologia , Aracnídeos , Modelos Animais de Doenças , Quimioterapia Combinada , Histocitoquímica , Ratos , Resultado do Tratamento , Calcificação Vascular/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...